Insertion Type EMFM

MODEL NO. EMF‐I

Electro‐magnetic flowmeter consists of sensor through which the measured liquid flows. The electronic convertor amplifies the low level signal from sensor. The output signal is proportional to the volume flow rate of measured liquid. The EMF can be used where the measured liquid is conductive and non‐magnetic.

Features

Line size: 1000mm & above

Empty pipe detection

Two line LCD display, 16 characters per line or graphical display

GSM/GPRS connectivity

In‐built data logger

Bi‐directional flow measurement

Isolation valve for sensor

Specifications

DN 1000 & above
6 Kg/cm² / 10Kg/cm² / 16 Kg/cm²
SS 316 / Hastalloy C / Titanium / Tantalum
≥ 20 μS/cm
Integral or Remotely mounted
0.5 to 10 m/s
Flanged or Threaded
Upstream 15D, Dowstrem 10D
± 0.5% of FS
±0.2%
Back‐lit LCD , 2 line 16 characters or graphical display
Totalised Flow: m3 / L
Instantaneous Flow: m3/hr, m3/min, m3/sec
L/hr , L/min , L/ sec
4 ‐20mA (std.), RS 232 MODBUS / RS 485 MODBUS
90 to 265 V AC
IP65

Insertion Type EMFM